Low-cost J-Link for educational purpose J-LINK EDU is identical to J-Link BASE and offers the same functionality. It has been designed to allow students and educational facilities as well as hobbyists access to top of the line debug probe technology.
Overview
The J-Link EDU license includes the unlimited breakpoints in flash memory feature. With the Flash Breakpoints, developers may set an unlimited number of breakpoints in flash memory helping to debug applications that run from flash memory.
As a legitimate owner of a SEGGER J-Link, you can always download the latest software free of charge. Though not planned and not likely, we reserve the right to change this policy. Note that older models may not be supported by newer versions of the software. Typically, we support older models with new software at least 3 years after end of life.
Supports concurrent access to CPU by multiple applications:J-Link allows multiple applications to access a CPU at the same time. This has numerous applications. J-Link commander can be used in parallel to a debugger, a tool to communicate via DCC can be used in parallel to a debugger or a visualization tool such as Micrium's u/C-Probe or SEGGER's kernel viewer embOSView. This feature is currently not available for Cortex A and R cores.
Crossplatform support: runs on Windows, Linux, macOS. The MAC and Linux versions are fully usable, but limited to the following components:
J-Link Commander, command line GDBServer, shared library (DLL-equivalent)
Key features
- Supports a broad range of microcontrollers
- Multiple CPUs supported—8051, PIC32, RX, ARM7/9/11, Cortex-A/R/M, RISC-V
- Download speed up to 1 MB/s
- Supports unlimited breakpoints in flash memory, additional license required.
- Built-in VCOM functionality
Limitations - Licensing and Support
- J-Link EDU may only be used for non-commercial purposes.
- J-Link EDU does not come with support. In case of questions / problems, you can visit our community forum. However, there is no claim for guaranteed support in the forum. View forum rules for more information.
Specifications
Specification | Value |
---|---|
Supported OS | Microsoft Windows (x86 / x64 / Arm64), Linux (x86 / x64 / Arm / Arm64), macOS (x64 / Apple M1) |
Electromagnetic compatibility (EMC) | EN 55022, EN 55024 |
Operating temperature | +5°C ... +60°C |
Storage temperature | -20°C ... +65 °C |
Relative humidity (non-condensing) | Max. 90% rH |
Mechanical | |
Size (without cables) | 100mm x 53mm x 27mm |
Weight (without cables) | 70g |
Available Interfaces | |
USB interface | USB2.0 (Full-Speed), Micro USB |
Target interface | JTAG/SWD 20-pin |
JTAG/SWD Interface, Electrical | |
Power supply | USB powered Max. 50mA + Target Supply current. |
Target interface voltage (VIF) | 1.2V ... 5V |
Current drawn from target voltage sense pin (VTRef) | < 25µA |
Target supply voltage | 4.5V ... 5V (if powered with 5V on USB) |
Target supply current | Max. 300mA |
Reset type | Open drain. Can be pulled low or tristated |
Reset low level output voltage | VOL <= 10% of VIF |
For the whole target voltage range (1.2V <= VIF <= 5V) | |
LOW level input voltage (VIL) | VIL <= 40% of VIF |
HIGH level input voltage (VIH) | VIH >= 60% of VIF |
For 1.2V >= VIF <= 3.6V | |
LOW level output voltage (VOL) with a load of 10 kOhm | VOL <= 10% of VIF |
HIGH level output voltage (VOH) with a load of 10 kOhm | VOH >= 90% of VIF |
For 3.6 <= VIF <= 5V | |
LOW level output voltage (VOL) with a load of 10 kOhm | VOL <= 20% of VIF |
HIGH level output voltage (VOH) with a load of 10 kOhm | VOH >= 80% of VIF |
JTAG/SWD Interface, Timing | |
JTAG speed | Max. 15 MHz |
SWO sampling frequency | Max. 30 MHz |
Data input rise time (Trdi) | Trdi <= 20ns |
Data input fall time (Tfdi) | Tfdi <= 20ns |
Data output rise time (Trdo) | Trdo <= 10ns |
Data output fall time (Tfdo) | Tfdo <= 10ns |
Clock rise time (Trc) | Trc <= 3ns |
Clock fall time (Tfc) | Trc <= 3ns |
Terms of use
You may use the J-Link EDU for non profit educational purposes only! Non-profit educational purposes means that you may not use the J-Link EDU and its J-Link software:
- directly or indirectly in or for a profit organization or business purposes or other undertaking intended for profit.
- direct or indirect within any other commercial environment (e.g. office).
- to develop, debug, program or manufacture a commercial product (or parts thereof).
- to use it to either earn money or reasonably anticipate the receipt of monetary gain from it.
Any other use of the J-Link EDU is prohibited and illegal! If there is any doubt if a certain use may be considered within the foregoing scope or whether your use of the J-Link EDU applies to an educational situation, it is strongly recommended to get in touch and consult SEGGER prior use.
For clarification purposes: A student using the J-Link EDU direct or indirect in a business or profit organization (e.g. company) is considered a violation of the scope of this agreement.
Note: Before connecting with the J-Link EDU you need to accept the Terms of use as shown on the screen below:
How to purchase J-Link EDU
In case you would like to purchase the J-Link EDU, please contact AK-Modul-Bus. J-Link EDU is sold to students, teachers, universities, schools or other non-commercial educational institutions only.
Package Content
J-Link EDU
.1" 20-pin ribbon cable
USB cable